Key Specifications

  • 0.1 to > 5 Terahertz
  • 70 to 80 dB Dynamic range
  • 1550 ± 10 nm Femtosecond Laser
  • InGaAs Photoconductive Emitter and Receiver
  • Standard Scan Range: 100 ps to 2000 ps (custom)
  • Fast Scan Range: 5 ps 10 ps, 20 ps, 50 ps and 100 ps
  • Integrated Camera on THz Sensor

Salient Features

  • Research friendly THz Platform
  • 0.1 to > 5 Terahertz Broadband
  • Compact – Table Top Model
  • Customizable Setup with Transmission and Reflection
  • Suitable for Spectroscopy and Imaging measurements

Dedicated Workflow

High Resolution

Accurate Results

Customizable Setup

Salient Features of Terahertz Spectroscopy +
Integrated THz Measurement and Analysis
One platform for terahertz time-domain acquisition and frequency-domain analysis, from raw waveform to interpretable material insights.
Compact Table-Top Design
A lab-friendly footprint suitable for research environments where flexibility, ease of setup, and accessibility matter.
Transmission and Reflection Capability
Configurable hardware architecture for transmission and reflection measurements, enabling broader sample compatibility.
Spectroscopy and Imaging Ready
Supports both point spectroscopy and area-based imaging workflows for material evaluation, thickness gauging, and layer analysis.
Software-Driven Workflow
Dedicated software for acquisition, visualization, control, and post-processing, reducing setup complexity for routine users.
Upgradable Research Platform
Can be configured with accessories such as imaging stages, reflection modules, polarizers, and purging options.

TeraXplor™ is a turn-key versatile THz system designed and developed for research and academic researchers to do fast and easy terahertz time-domain measurements in minimal time. It comes with a broadband 0.1 to > 5 THz bandwidth and 70 to 80 dB dynamic range. This terahertz system is powered with a 1550 nm +/- 10 nm femtosecond laser source and InGaAs photoconductive emitter and receiver. The best-in-class optical delay unit (ODU) gives ability to user conduct scan range from 5 ps to 2000 ps and capable of integrating the voice-coil delay unit to achieve scan speed up to 20 Hz. Integration of TeraLumen’s voice coil delay unit enable use to collect data in less than 1 second for 20 picoseconds. A dedicated software, Lumen Lite v3.2, was developed to automate the switch-on, data acquisition, and controlling the stages for faster measurements and analysis. This powerful software can plot Time Pulse, FFT Plot, absorption coefficient, refractive index, thickness, and imaging.

Unlike premium ultra-high-spec systems that are optimized around maximum bandwidth and dynamic range, TeraXplor™ is positioned as a practical and adaptable platform for research teams that value usability, configurable geometry, integrated software, and application-focused workflow development.


Transmission Mode: The THz pulse passes through the sample and is collected on the opposite side. It is suited for thin, semi-transparent materials like polymers, coatings, and tissues. This mode reveals absorption and refractive index changes as the wave propagates.

Reflection Mode: The THz pulse is directed onto the sample surface and the reflected signal is measured from the same side. It is best for opaque or thick materials like metals, ceramics, and composites where transmission is not feasible. This mode enables analysis of surfaces, multilayers, and buried interfaces through time-delayed echoes.

Applications in Research and Academic

Lumen Lite Software Basic Features

Pulse

Data saving in *csv

File management

System controls

System Specifications

Laser Source 1550 ± 10 nm femtosecond laser
Laser Repetition Rate
100 MHz
THz Technology Type
Time Domain Signal
Spectral Range
0.1 to > 5 THz
THz Emitter / Receiver
InGaAs photoconductive emitter and detector
Standard Probe Setup
Transmission
Sensor Integration
Camera/Depth Sensor/ Laser
THz Focus Type
Collimated, Focused
THz Focal Spot
6 mm, 2 mm
Working Mode
Transmission and Reflection
Dynamic Range
70 to 80 dB
Average Power
100 µW
Standard Scan Range
330 ps, 600 ps, 1000 ps, and 2000 ps
Scan Speed
5 ps/s
Fast Scan Range
5 ps, 10 ps, 20 ps, 50 ps and 100 ps
Scan Speed
20 Hz
THz Frequency Resolution
< 1.2 GHz
Computer Interface
USB
Integrated Camera
8MP Camera on THz sensor
Compatible Software
Lumen Lite
Optional Accessories

• 45° Reflection Probe setup
• 2-axis Motorized Stage for Imaging
• 180° semi-circular manual stage
• Nitrogen Purging Setup
• 300 mm x 150 mm Bread board
• THz Polarizer
• Optical Fiber Cleaning kit
• TPX Terahertz Lens

Power and Dimensions

Operating Voltage 230 VAC, 10A
Power Consumption
< 500 W
Ambient Atmosphere
<25 °C, 80% RH
Operating Temperature
18° – 40 °C
Controller (L x W x H)
40 cm x 30 cm x 15 cm
Controller Weight
18 Kg
THz Sensor Weight
< 500 Grams

Lumen Lite Software and Imaging Specifications

Travel Range 75 mm x 75 mm x 75 mm
Resolution X – Axis
< 250 μm* ( Stage resolution < 10 μm )
Resolution Y – Axis
< 250 μm* ( Stage resolution < 10 μm )
Resolution Z – Axis
Stage resolution < 10 μm
Load Capacity X-Axis
> 3 kg
Actuator
Stepper motor

Note: Turnkey system is customizable based on application requirements.

TeraXplor Accessories

Open

Maintenance kit for safe cleaning of fiber connectors and mating sleeves to preserve coupling efficiency and system reliability.

Open

Low-loss THz lenses for beam focusing and collimation, suitable for optimizing spot size, standoff, and experimental flexibility.

Standard Scope of Supply

Controller

Transmission Head

THz-TDS Lumen Lite Software

Cable set

Integrated PC

UPS

Standard Scope of Supply

The TeraXplor™ scope comprises with

Multi-layer coating thickness measurement,Analytical and Pharma

Controller

Multi-layer coating thickness measurement,Analytical and Pharma

Probe Head

Multi-layer coating thickness measurement,Analytical and Pharma

THz-TDS Lumen Lite Software

Multi-layer coating thickness measurement,Analytical and Pharma

Cable

set

Multi-layer coating thickness measurement,Analytical and Pharma

Transmission

Jig

Multi-layer coating thickness measurement,Analytical and Pharma

Reflection

Jig

Multi-layer coating thickness measurement,Analytical and Pharma

Integrated PC

Multi-layer coating thickness measurement,Analytical and Pharma

UPS

Optional

Note: Turnkey system is customizable based on application requirements.

TeraXplor™ Terahertz Spectroscopy System
Measure Material Properties Without Contact

Characterize dielectric properties, refractive index, absorption and frequency-dependent material response in research samples.

TeraXplor Terahertz Spectroscopy System
0.1 to >5 THzSpectral Range
70-80 dBDynamic Range
<1.2 GHzFrequency Resolution
330-1200 psOptical Delay Scan Options
Transmission + ReflectionWorking Modes
1550 ± 10 nmFemtosecond Laser
Research outcomes

What Can You Measure with TeraXplor?

Move from a terahertz waveform to material-level information using a configurable THz-TDS research platform.

Time Domain Spectroscopy

Acquire THz time-domain pulses and analyze the signal in ps and corresponding amplitude.

Fast Fourier Transform Analysis

Plot frequency domain Spectrum in THz bandwidth either in atmospheric condition or with nitrogen purging.

THz Imaging

Extend point spectroscopy into spatial mapping using optional motorized scanning configurations.

Refractive Index

Extract frequency-dependent refractive-index information from suitable dielectric materials.

Absorption Coefficient

Evaluate terahertz absorption behaviour and compare material response across frequency.

Layer Thickness

Investigate suitable dielectric layers and multilayer structures using time-of-flight information.

Built for adaptable research

Why Researchers Choose TeraXplor

Broadband THz measurement, configurable geometry, imaging readiness and integrated software in one research platform.

Flexible Measurement Configurations

Configure TeraXplor for THz transmission, reflection and custom spectroscopy experiments.

Integrated THz Acquisition & Analysis

Acquire THz data, view time-domain pulses, FFT spectra and analyze material properties in Lumen Lite.

Integrated 8 MP Camera

Camera integration on the THz sensor supports practical alignment during research measurements.

High-Resolution Spectroscopy

Broadband 0.1 to >5 THz spectroscopy with <1.2 GHz frequency resolution for material research.

THz Imaging Ready

Add motorized scanning for repeatable spatial measurements and THz imaging workflows.

Modular Research Platform

Configure reflection probes, polarizers, purging, stages, lenses and custom accessories.

Lumen Lite

Integrated THz Measurement & Analysis Software

A unified workflow for system control, THz acquisition, visualization, file management and core material analysis.

System ControlOperate configured measurement functions from one interface.
Pulse & FFTVisualize time-domain and frequency-domain results.
Material PropertiesRefractive index and absorption coefficient analysis.
Thickness & ImagingSupport configured thickness and imaging workflows.
File ManagementOrganize measurement files and datasets.
CSV & ReportingSave data and support report generation.
Lumen Lite Software Interface
Flexible measurement configurations

One THz Platform. Multiple Research Configurations.

Select a measurement geometry that fits the sample and research objective, then expand the setup as the project evolves.

TeraXplor transmission and reflection configurations

Transmission THz-TDS

The THz pulse passes through the sample and is detected on the opposite side — suitable for appropriate THz-transmitting or semi-transparent samples.

✓Material spectroscopy and dielectric characterization
✓Refractive index and absorption analysis
✓Polymer, pharmaceutical and dielectric research
TeraXplor reflection configuration

Reflection THz-TDS

Measure the reflected THz response from the same side of the sample when transmission geometry is impractical.

✓Surface and interface investigations
✓Suitable coating and multilayer studies
✓Optional 45° reflection probe configuration

Motorized THz Imaging

Add motorized scanning to convert point measurements into repeatable spatial scans for material mapping and imaging studies.

✓75 mm × 75 mm × 75 mm standard imaging kit
✓Stage resolution is 250 µm
✓Customizable X, Y and Z scanning options
Proven Terahertz Research Application
01

Material Characterization

Study broadband THz response, amplitude and phase information, refractive index and absorption behaviour of suitable materials.

Discuss a material →
02

Polymers & Dielectrics

Investigate dielectric properties and compare terahertz response across polymers and non-conductive research samples.

Discuss a sample →
04

Coatings & Multilayers

Explore suitable dielectric layer thickness, interfaces and multilayer structures with non-contact terahertz measurements.

Discuss a coating →
05

THz Imaging & NDT R&D

Combine spectroscopy with motorized scanning for spatial studies, quality research and non-destructive evaluation.

Discuss imaging →
06

Liquids, Gases & Custom Studies

The brochure lists liquids and gases analysis and supports customizable measurement setups for application-specific research.

Discuss your experiment →
FULL SPECIFICATIONS

TeraXplor Terahertz Spectroscopy System Specifications

System
Power & Dimensions
Laser Source1550 ± 10 nm femtosecond laser
Laser Repetition Rate100 MHz
THz Technology TypeTime Domain Signal
Spectral Range0.1 to > 5 THz
THz Emitter / ReceiverInGaAs photoconductive emitter and detector
Working ModeTransmission and Reflection
Dynamic Range70 to 80 dB
Average Power100 µW
Standard Scan Range330 ps, 600 ps, 1200 ps
THz Frequency Resolution< 1.2 GHz
Compatible SoftwareLumen Lite
Operating Voltage230 VAC, 10 A
Power Consumption< 500 W
Ambient Atmosphere< 25 °C, 80% RH
Operating Temperature18° – 40 °C
Controller (L×W×H)40 × 30 × 15 cm
Controller Weight18 Kg
THz Sensor Weight< 500 Grams
Travel Range75 mm × 75 mm × 75 mm
Resolution X-Axis< 250 µm*
Resolution Y-Axis< 250 µm*
Axis Resolution Stage< 10 µm
Load Capacity< 3 kg
ActuatorStepper motor

*Turnkey system is customizable based on application requirements.

Configure your system

Expand TeraXplor Around the Experiment

THz accessories extend TeraXplor's capabilities for diverse sample geometries, imaging needs, and research workflows.

Open
TPX terahertz lenses for TeraXplor

Low-loss THz lenses for beam focusing and collimation, supporting spot-size and experimental-geometry optimization.

45° Reflection Probe Setup

THz Polarizer

Nitrogen Purging Kit

180° Semi-Circular Manual Stage

THz Breadboard

Check out Our Products

Biomedical

TeraMARGIN

Industrial

TeraNIM

Phanindra Kumar - Business Head - NDT

Talk to an applications Expert

Tell us your sample type and measurement goal — we'll recommend the right configuration and reflection/transmission setup before you buy.

Dr. Srikanth
Technical Commercial Engineer